Manufacturer: Siemens
ET 200AL, , AI 4XU/I/RTD, 4X M12, IP67
Available for Back Order
SIMATIC ET 200AL, AI 4XU/I/RTD, 4x M12, Degree of protection IP67 SIMATIC ET 200AL is a modular, distributed I/O system with compact I/O modules in IP65/67. With the I/O system, Siemens offers you a space-saving solution. Your space requirements are kept to a minimum because SIMATIC ET 200AL can easily be mounted on the machine or assembly line in any position thanks to its small width of 30 mm and low weight of 145 g. The system is not only space-saving but can also be used at temperatures between -25 °C and +55 °C due to its extraordinarily rugged housing, which is splashproof, oil-tight and dust-tight. You can put the SIMATIC ET 200AL into operation immediately due to its hassle-free and fast configuration. This can be done in an uncomplicated way because of the CAx-compatible labeling of all interfaces via the TIA Portal. The color assignment of the cables to the interfaces and simple wiring are ensured by a unique color-coded identification system. Siemens guarantees a future-proof investment due to the inclusion of innovative and long-life automation products. By already using tomorrow's technologies today, Siemens is redefining market standards. They are available as digital and analog input and output modules and as mixed modules (digital). The sensors are connected with the M8 or M12 connection system. The modules can be optionally connected to PROFINET or PROFIBUS or integrated into SIMATIC ET 200SP.
Datasheets and Manuals
Product Information
Manufacturer: | Siemens |
Pricing Unit: | Each |
Weight: | 0.191 kg (each) |
Tariff code: | 85389091 |
Generic code: | SIEMNOP |
GTIN/UPC/EAN: | 4047623403463 |
Product Details
ETIM Group: | Programmable logic controllers PLC |
ETIM Class: | Fieldbus, decentr. periphery - analogue I/O module |
Type of electric connection: | Plug-in connection |
Voltage type of supply voltage: | DC |
Degree of protection (IP): | IP65/IP67 |
Explosion safety category for gas: | None |
Explosion safety category for dust: | None |
Width: | 30mm |
Number of analogue inputs: | 4 |
Number of HW-interfaces USB: | 0 |
Number of analogue outputs: | 0 |
Resolution of the analogue outputs: | - |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces serial TTY: | 0 |
Number of HW-interfaces Wireless: | 0 |
Resolution of the analogue inputs: | 16Bit |
Number of HW-interfaces industrial Ethernet: | 0 |
Number of HW-interfaces other: | 0 |
Number of interfaces PROFINET: | 0 |
Depth: | 40mm |
Number of HW-interfaces RS-232: | 0 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 0 |
Height: | 159mm |
Supply voltage AC 50 Hz: | - - |
Supply voltage AC 60 Hz: | - - |
Supply voltage DC: | 20.4 - 28.8V |
Suitable for safety functions: | false |
Supporting protocol for INTERBUS: | false |
Wall mounting/direct mounting: | true |
Input, thermocouple: | false |
Radio standard Wi-Fi 802.11: | false |
Supporting protocol for AS-Interface Safety at Work: | false |
System accessory: | true |
Output, voltage: | - |
Radio standard GPRS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Supporting protocol for other bus systems: | false |
Input, current: | true |
Supporting protocol for Data-Highway: | false |
Supporting protocol for LON: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SUCONET: | false |
Input, resistance thermometer: | true |
Radio standard Bluetooth: | false |
Rail mounting possible: | true |
Supporting protocol for CAN: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for PROFIBUS: | false |
Appendant operation agent (Ex ib): | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SafetyBUS p: | false |
Analogue outputs configurable: | - |
Fieldbus connection over separate bus coupler possible: | true |
Front built-in possible: | true |
Input signal, configurable: | true |
Input, resistor: | true |
IO link master: | false |
Output, current: | - |
Rack-assembly possible: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | false |
Analogue inputs configurable: | true |
Appendant operation agent (Ex ia): | false |
Input, voltage: | true |
Output signal configurable: | - |
Radio standard GSM: | false |
Radio standard UMTS: | false |
Supporting protocol for ASI: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for SERCOS: | false |
Supporting protocol for TCP/IP: | false |
All shipping options below are for Ireland. Delivery prices below are Exc VAT.
Web Promo Carriage | IE standard delivery, usually within 1 - 2 days (1 per day, minimum order €25.00) | €0.00 |
Standard 1-2 Days | IE standard delivery, usually within 1 - 2 days | €10.00 |
Collect | Collection is available from our site - please call if your order is urgent | €0.00 |
International Delivery
We currently only provide international shipping to Northern Ireland.
We offer a very competitive and fast delivery service; however, if you prefer to collect using your own courier, then we can also arrange that at no extra cost.
Our technical team can help find an alternative! Fill in the below to get started.