SWITCH MODE DIN RAIL POWER SUPPLY, 85-264V AC AC INPUT, 24V DC DC OUTPUT
Additional Stock
2 in global warehouse
List of Models
Power ratings | Input voltage | Output voltage | Output current | Model number |
15W | 100 to 240 VAC | 24 VDC | 0.65A | S8VS-01524 |
30W | 1.3A | S8VS-03024 | ||
60W | 2.5A | S8VS-06024 | ||
120W | 5A | S8VS-12024 | ||
240W | 10A | S8VS-24024 | ||
480W |
|
S8VS-48024 |
Specifications
Item | Power ratings | 15W | 30W | 60W | |
Efficiency (typical) | 77% min. | 80% min. | 78% min. | ||
Input | Voltage*1 | 100 to 240 VAC (85 to 264 VAC) | |||
Frequency *1 | 50/60 Hz (47 to 450 Hz) | ||||
Current | 100V input | 0.45 A max. | 0.9 A max. | 1.7 A max. | |
200V input | 0.25 A max. | 0.6 A max. | 1.0 A max. | ||
Power Factor | -- | ||||
Harmonic current emissions | Conforms to EN61000-3-2 | ||||
Leakage current | 100V Input | 0.5 mA max. | |||
200V Input | 1.0 mA max. | ||||
Inrush current *2 | 100V Input | 25 A max. (for a cold start at 25°C) | |||
200V Input | 50 A max. (for a cold start at 25°C) | ||||
Output | Voltage adjustment range *3 | 10% to 15% (with V.ADJ) | |||
Ripple | 2.0% (p-p) max. (at rated input/output voltage) | ||||
Input variation influence | 0.5% max. (at 85 to 264 VAC input, 100% load) | ||||
Load variation influence (rated input voltage) | 2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load) | 1.5% max. (with rated input, 0 to 100% load) | |||
Temperature variation influence | 0.05%/°C max. | ||||
Startup time *2 | 100 ms max. (at rated input/output voltage) | 1,000 ms max. (at rated input/output voltage) | |||
Hold time *2 | 20 ms min. (at rated input/output voltage) | ||||
Additional functions | Overload protection *2 | 105% to 160% of rated load current, voltage drop, automatic reset | 105% to 160% of rated load current, voltage drop, intermittent operation, automatic reset | ||
Overvoltage protection *2 | Yes (a zener diode clamp) *4 | Yes *5 | Yes | ||
Undervoltage alarm indication | Yes (color: red) | No | |||
Parallel operation | No | ||||
Series operation | Yes for up to 2 Power Supplies (with external diode) | ||||
Other | Operating ambient temperature | Refer to the derating curve in Engineering Data. (with no icing or condensation) | |||
Storage temperature | 25 to 65°C | ||||
Operating ambient humidity | 25% to 85% (Storage humidity: 25% to 90%) | ||||
Dielectric strength |
|
||||
Insulation resistance | 100 M/min. (between all outputs and all inputs/ PE terminals) at 500 VDC | ||||
Vibration resistance |
|
||||
Shock Resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions | ||||
Output indicator | Yes (color: green) | ||||
EMI | Conducted Emissions | Conforms to EN61204-3 EN55011 Class B and based on FCC Class A | Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A | ||
Radiated Emissions | Conforms to EN61204-3 EN55011 Class B | Conforms to EN61204-3 EN55011 Group 1 Class B | |||
EMS | Conforms to EN61204-3 high severity levels | ||||
Approved standards |
|
|
|||
SEMI | F47-0200 (200 VAC input) | ||||
MTBF *7 | > 500.000 hrs | > 250.000 hrs | |||
Weight | 160g max. | 180g max. | 330g max. |
- Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
- Refer to Engineering Data on page 7 of the PDF datasheet for details.
- If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
- The overvoltage protection of the S8VS-01524 uses a zener diode clamp. If the internal feedback circuit is destroyed by any chance, the load may be destroyed by the clamped output voltage (approx. 140% to 190% of the rated output voltage).
- To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
- To ensure the emission rating, a ferrite ring core should be used in all cabling (SEIWA E04SR301334 or equivalent model).
- MTBF stands for mean Time Between Failures, which is calculated according to the probability of accidental device failures and indicates the reliability of devices.
Datasheets and Manuals
Product Information
Alternative Part Number: | 307948 |
Manufacturer: | Omron |
Pricing Unit: | Each |
Weight: | 0.170 kg (each) |
Tariff code: | 85044030 |
Generic code: | ODD |
GTIN/UPC/EAN: | 4547648711579 |
Product Details
ETIM Group: | Low-voltage industrial components |
ETIM Class: | DC-power supply |
1st secondary output voltage: | 21.6 - 27.6V |
Built-in height: | 96.4mm |
Built-in width: | 22.5mm |
Depth: | 96.4mm |
Direct mounting possible: | No |
Height: | 85mm |
Max. output current 1: | 0.65A |
Modular version: | Yes |
Nominal value output current 1: | 0.65A |
Nominal value output voltage 1: | 24V |
Output voltage stabilized: | Yes |
Performance level acc. EN ISO 13849-1: | None |
Power consumption: | 44VA |
Power output: | 15W |
Rail mounting possible: | Yes |
Rated supply voltage at AC 50 Hz: | 100 - 240V |
Rated supply voltage at AC 60 Hz: | 100 - 240V |
Secondary voltage adjustable: | Yes |
Short-circuit-proof: | No |
SIL according to IEC 61508: | None |
Stabilized: | Yes |
Suitable for safety functions: | Yes |
Type of electric connection: | Screw connection |
Voltage type of supply voltage: | AC |
Wall mounting possible: | Yes |
Width: | 22.5mm |
Width in number of modular spacings: | 1 |
Dimensions (Unpackaged)
Quantity | Height | Width | Length | Weight |
---|---|---|---|---|
1 | 92 mm | 22 mm | 96 mm | 126 g |
All shipping options below are for Ireland. Delivery prices below are Exc VAT.
Web Promo Carriage | IE standard delivery, usually within 1 - 2 days (1 per day, minimum order €25.00) | €0.00 |
Standard 1-2 Days | IE standard delivery, usually within 1 - 2 days | €10.00 |
Collect | Collection is available from our site - please call if your order is urgent | €0.00 |
International Delivery
We currently only provide international shipping to Northern Ireland.
We offer a very competitive and fast delivery service; however, if you prefer to collect using your own courier, then we can also arrange that at no extra cost.
Our technical team can help find an alternative! Fill in the below to get started.